產品列表PRODUCTS LIST
丙烯酸氣體檢測管 216S ACRYLIC ACID (+) CH2=CHCOOH 1-50ppm,氣體檢測管是用來檢測某種氣體在某一環境中所含濃度的簡易檢測裝置,通過檢測劑與被檢測氣體的反應而出現顏色變化,來表示所測環境中的氣體濃度。在不用任何能源、電源的情況下,具有操作簡單、使用范圍廣、檢測準確、即時性強和經濟的特點。
更新時間:2024-10-23
在線留言丙烯酸氣體檢測管 216S ACRYLIC ACID (+) CH2=CHCOOH 1-50ppm
Tube No.216S
1. PERFORMANCE
1) Measuring range :1-50 ppm
Number of pump strokes 1(100ml)
2) Sampling time :1.5 minutes/1 pump stroke
3) Detectable limit :0.2 ppm
4) Shelf life :3 years
5) Operating temperature :0~40℃
6) Temperature compensation :Necessary(See "TEMPERATURE CORRECTION TABLE")
7) Reading :Direct reading from the scale calibrated by 1 pump stroke
8) Colour change :Pale Pink→Yellow
2. RELATIVE STANDARD DEVIATION
RSD-low:15% RSD-mid.:10% RSD-high:10%
3. CHEMICAL REACTION
By reacting with alkali,PH indicator is discoloured.
CH3COOH+NaOH→CH3CO2Na+H2O
4. CALIBRATION OF THE TUBE
DIFFUSION TUBE METHOD
5. INTERFERENCE AND CROSS SENSITIVITY
3
1
ppm
100ml
GAS To pump
5
10
20
30
40
50
216S ACETIC ACID
Substance ppm Interference ppm Coexistence
Sulphur dioxide Similar stain is produced. 1/20×Acetic Higher readings are given.
acid
Nitrogen dioxide 300 〃10 Unclear stain is produced.
Hydrogen chloride Pink stain is produced. 2×Acetic FIG.1 acid Higher readings are given.
Chlorine FIG.2 Yellow stain is produced. 5 〃
TEMPERATURE CORRECTION TABLE
Scale True Concentration (ppm)
Readings 0℃ 10℃ 20℃ 30℃ 40℃
(ppm) (32°F) (50°F) (68°F) (86°F) (104°F)
50 63 57 50 45 40
40 50 45 40 36 31
30 37 33 30 27 23
20 24 22 20 18 16
10 12 11 10 9 8
5 6 6 5 5 4
3 4 4 3 3 2
1 1 1 1 1 1
0
50
30
20
40
10
Hydrogen chloride〔ppm〕?
FIG.1 Influence of Hydrogen chloride
Acetic acid indicating value 〔ppm〕
100 200 300
Coexistence
Interference
0
60
20
40
Chlorine〔ppm〕?
FIG.2 Influence of Chlorine
Acetic acid indicating value 〔ppm〕
250 500
Coexistence
Interference
www.r-biopharm.com.cn